Installation manual

- 23 -
Test Mode D29-D47
D29 CombiWash water
Only possible on ovens with CombiWash.
This function activates solenoid valve MV4.
You activate or deactivate the function by pressing the step key.
To pulse, press the alarm key.
0= OFF, 1= ON.
D34 Water pressure sensor
Here it is possible to read the status of P7.
OF|HI= water pressure adequate, ON|LO= water pressure inadequate.
D36 Steam generator thermo-switch
Here it is possible to read the status of Q3
In the display next to ”Time”, it is shown whether the circuit is connected or disconnected.
OF= disconnected ON= connected.
In the event of defects in the oven, it is possible to reset thermo-switch Q3 which is located at
the bottom of the oven below the operation panel.
D37 Motor RPM 1
Here it is possible to read the number of revolutions for fan motor 1.
The number of revolutions is shown in the display next to the temperature key.
D38 Motor RPM 2
Available on 1.16 and 1.20 models only.
Here it is possible to read the number of revolutions for fan motor 2.
The number of revolutions is shown in the display next to the temperature key.
D46 Temperature CPU board
Here it is possible to read the temperature of the CPU board.
In the display next to ”Temperature”, the temperature of the CPU board is shown. Max 60°C.
D47 Temperature IO board
Here it is possible to read the temperatures of the IO board.
In the display next to ”Temperature”, the temperature of the IO board is shown. Max 60°C.