Installation guide

Power Supply Cord Direct Wire
1.
2.
3.
Eiectricam Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power suppmy cord,
Pmuginto a grounded outmet.
Failure to follow these instructions can result in death,
fire, or electrical shock,
Disconnect power.
Remove the terminal block cover screws located on the back
of the range. Pull cover down and toward you to remove cover
from range.
'B
C
A. Two mounting tabs each side
B. Terminal block cover
C. Hex-head screws
Complete installation following instructions for your type of
electrical connection:
4-wire (recommended)
3-wire (if 4-wire is not available)
Emectrica} Shock Hazard
Disconnect power before servicing,
Use 8 gauge copper or 6 gauge amuminum wire.
EmectricaJJy ground range.
Failure to follow these instructions can resumt in death,
fire, or eJectdcam shock.
Electrical Connection Options
If your home has: And you will be Go to Section:
connecting to:
4-wire receptacle A UL listed,
(NEMA type 14-50R) 250-volt
minimum,
40-amp, range
power supply
cord
4-wire connection:
Power supply cord
4-wire direct
(12.7 cm)
A fused
disconnect or
circuit breaker
box
4-wire connection:
Direct wire
3-wire receptacle A UL listed,
(NEMA type 10-50R) 250-volt
minimum,
40-amp, range
power supply
cord
3-wire connection:
Power supply cord
3-wire direct A fused
_,, disconnect or
/2.__ circuit breaker
box
3-wire connection:
Direct wire