Specifications

Features
Built to perform in the
harshest environments
Offshore oil rigs, on-shore oil company
ofces and reneries
Petrochemical sites and propane ll-up
stations
Paint and varnish storage or processing
plants
Grain alcohol processors or storage sites
Plant areas using strong solvents or
chemicals
Munitions plants or armories
PVC or plastics plants and processing points
• Recycling plants
Furniture renishing/stripping workshops
• Fertilizer plants
Ofce complexes where methane is a by-
product
• Hazardous materials storage
• Container labs
• For analyzer houses/shelters
Applications
• Permanent split capacitor motor
• Hermetically sealed refrigeration system
• Environmentally sealed on/off switch and gold plated contacts in
thermostat for corrosion resistance
• Solid-state control relays for compressor and fan operation
• Hot gas bypass allows the air conditioner to operate at low ambient
conditions without freezing at outdoor temperatures as low as 45° F (7°C)
• Hermetically sealed reciprocating compressor is cooled during the
refrigeration cycle, which allows the unit to tolerate
higher outdoor temperatures up to 130˚ F (55°C)
• Larger, commercial grade, enclosed fan motor with
hermetically sealed overload for arc-free operation.
Totally enclosed to assure efcient operation under
adverse electrical conditions
• Unit utilizes eld supplied, direct-wired, 15-amp circuit
with time-delay fuse that will tolerate current surge
without tripping the breaker
• 22-gauge, G60 steel air conditioner cabinet is powder
coated for corrosion protection and to withstand years of
hard use
• High density EPS foam insulation for thermal resistance
and sound control
• Heavy duty hexacomb packaging resists damage during shipment and is
environmentally friendly
5-stage ecoat
COILS COATED FOR CORROSION RESISTANCE
MODEL SH24M20
• ElectroFin
®
5-stage, immersion ecoat process on 100% of metallic
surfaces on the outdoor coil provides outstanding corrosion resistance
protection in coastal or corrosive environments
ELECTROFIN BENEFITS:
• Excellent adhesion characteristics
• Less than 1% thermal degradation
• Outstanding chemical resistance
• Passed 6048 hrs.ASTM B-117 Salt Spray
ELECTROFIN MEETS THE FOLLOWING:
• MIL-C-46168 Chemical Agent Resistance
-
DS2, HCI Gas
• CID A-A-52474A (GSA)
• MIL-STD 810F, Method 509.4 (Sand and Dust)
• MIL-P-53084 (ME)-TACOM Approval
• MIL-DTL-12468 Decontamination Agent (STB)
• DPG (Douglas Proving Grounds) Soil & Water Exposure Tests
• GM9540P-97 Accelerated Corrosion Test (120 cycles)
• ASTM B117-G85 Modied Salt Spray (Fog) Testing-2,000 hours
• ASTM B117 Salt Spray (tested by ARL for Lockheed Martin)
MODELS SH15M30A, SH20M30A, SH20M50A
• Diamonblue Advanced Corrosion Protection
®
on the
outdoor coil protects the coil against deterioration and
extends the life of the unit especially in coastal or
corrosive environments
LISTED
PORTABLE AIR CONDITIONERS
183H
Due to continuing engineering research and technology, specications are subject to change without notice. Manufactured under U.S. Design
Patent DES 368, 306 decorative front; Utility Patent 5, 622, 058. MAXIMUM outdoor ambient operating temperature is 130°F. (55°C) MAXIMUM
TEMPERATURE RATING FOR CLASS I, DIVISION 2, GROUPS A,B,C,D.
For global applications, Hazardgard cooling capacities are tested in a certied laboratory at moderate (T1*) and hot (T3*) climate conditions in
accordance with SASO (Saudi Arabian Standards Organization) Standard 2681. SASO Standard 2681 is adopted from ISO Standard 5151 for testing
and rating for performance of non-ducted air conditioners and heat pumps.
* Capacity and efciency values at each climate conditions are available upon request.
Specifications
Installation Information
Model
Dimensions
INCHES
Window Width
INCHES
In-Wall Installation
Finished Hole INCHES
Circuit Rating
Breaker or
T - D Fuse
Weight
Lbs.
Height Width
Depth with
Front
Depth J Box
to Louvers
Minimum
Extension
Into Room
Minimum
Extension
Outside Min. Max. Height Width Max. Depth Volts - Amps Net Shipping
SH15M30A 15
15
/
16” 25
15
/
16” 27
3
/
8” 6 3
1
/
16” 16
15
/
16” 27
7
/
8” 42 16
3
/
16” 26
3
/
16” 6 250V-15 140 167
SH20M30A 17
15
/
16” 25
15
/
16” 27
3
/
8” 6 3
1
/
16” 16
15
/
16” 27
7
/
8” 42 18
3
/
16” 26
3
/
16” 6
250V-15
(230V)
166 170
250V-20
(208V)
SH20M50A 17
15
/
16” 25
15
/
16” 27
3
/
8” 6 3
1
/
16” 16
15
/
16” 27
7
/
8” 42 18
3
/
16” 26
3
/
16” 6 250V-15 171 175
SH24M20 17
15
/
16” 25
15
/
16” 27
3
/
8” 6 3
1
/
16” 16
15
/
16” 27
7
/
8” 42 18
3
/
16” 26
3
/
16” 6 250V-30 180 185
(A)
Front
SIDE VIEW
(A)
Junction
Box
Max.
Wall
Depth
Sleeve Dimensions Drawing
NOTE: Hazardgard unit
must be hard-wired.
Friedrich air conditioners can be found in some of
the world’s toughest locations. Oil companies rely
on us to cool offshore oil rigs in the most extreme
conditions.
Model
Cooling Capacity
Electrical Characteristics
Energy
Efciency
Ratio
Moisture
Removal
Air Direction
Controls Air Circulation Refrigerant
Cooling Cooling
Btu/Hr. Volts Rated Amps Watts EER
Pints/ HR CFM
60 HERTZ -NORTH AMERICA
SH15M30A 14500/14000 230/208 6.9/7.5 1495/1443 9.7/9.7 4.0 8-way 375 R-410A
SH20M30A 20000/19000 230/208 8.7/9.6 2125/2021 9.4/9.4 5.5 8-way 375 R-410A
SH24M20 24000/23700 230/208 12.6/13.5 2727/2788 8.8/8.5 8.0/ 7.5 8-way 385 R-401A
50 HERTZ -INTERNATIONAL
SH20M50A 19500/19100 240/220 9.8/10.3 2167/2156 9.0/9.0 5.6/5.5 8-way 425 R-410A
SH24M20 21000/20500 240/220 15.0/13.2 2600/2412 8.1/8.5 7.0/7.0 8-way 360 R-410A
31
30