Installation guide

Operating position
front leveffng leg
/
rear leveling leg
[] Remove cardboard shipping base from
under range. Remove storage drawer. Use a
3/8" drive ratchet to lower rear leveling legs
one-half turn. Use channel lock pliers to lower
front leveling legs one-half turn.
Before moving rangeacrossfloor, checkthat
range isstill on cardboard shipping base to
protect floor covering.
,, Making sure the
anti-tip bracket is _____
installed: _- __
Lookfor the anti-tip\ \\ _ _L_. _ \
anti-tip bracket bracket__
securely attached to _ range foot
floor.
Slide range back so rear range foot isunder
anti-tip bracket.
Replace storage drawer.
[]If installingthe range in a mobile
home, you MUST secure the range to the floor.
Any method of securing the range isadequate as
long as itconforms to the "Manufactured Home
Construction and Safety Standard," Page 2.
[] Place rack in oven. Place level on rack,
first side to side; then front to back.
If range is not level, pull range forward until
rear leveling leg is removed from the anti-tip
bracket. Use 3/8" drive ratchet and channel
lock pliers to adjust leveling legs up or down
until range is level. Push range back into
position. Check that rear leveling leg is
engaged in anti-tip bracket.
Note: Oven must be level for satisfactory
baking conditions.
Gas and electricalconnections
All connections must be wrench-tightened.
Typical rigid pipe connection
_ pressure
regulator 90Oelbow
90°olbo j .I ! blackiron
nipple union _-- pipe
union-- _ manual
gas
I I shutoff
nipple --_ialve
1/2"p 3/4" U
gas pipe L,J
Typical flexible connection
pressure
-- regulator
use pipe-joint
__ compound
90°elb I 1" "1 flexible
adapter_-- connector
L_ use pipe-joint
compound
adapter -- E_]_
manual
_2_ gas
L_ ]-- shutoff
1/2" to 3/4" _ U valve
gas pipe_
A 1/2" male pipe thread is needed for connection to
pressure regulator female pipe threads,
Om Use 15/16" combination wrench and
channel lock pliers to attach the flexible
connector to the adapters. Check that connector
is not kinked.
regulator shutoff valve in
"on" position
manual shutoff valve _
"open"poaition ..,_,,.,_
__ _;,upptv
[] Check that range regulator shutoff
valve is in the "on" position. Open the manual
shutoff valve in the gas supply line.
[]Apply pipe-joint compound made for
use with L. P. gasto the smaller thread ends of
the flexible connector adapters. Attach one
adapter to the pressure regulator elbow and
the other adapter to the gas shutoff valve.
Tighten both adapters.
[] Use a brush and liquid detergent
to test all gas connections. Bubbles around
connections will indicate a leak. If a leak
appears, shut off gas valve controls and
tighten connections. Then check connections
again. Never test for gas leaks with a match
or other flame. Clean all detergent from
range.
[] Center the burner cap on burner
base. Burner cap should be level when
properly positioned. Place burner grates
over burner.
[] Plug power supply cord into
grounded electrical outlet.
Page 5