30" (76.2 CM) RANGE HOOD LINER Installation Instructions and Use & Care Guide CAISSE DE HOTTE POUR Instructions d’installation et Guide d’utilisation et d’entretien Table of Contents/Table des matières ..................................... 2 IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. FOR RESIDENTIAL USE ONLY. IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS. POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.
TABLE OF CONTENTS RANGE HOOD SAFETY .................................................................2 INSTALLATION REQUIREMENTS.................................................4 Tools and Parts.............................................................................4 Location Requirements ................................................................4 Venting Requirements ..................................................................5 Electrical Requirements .....................................
IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ■ Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. ■ Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.
INSTALLATION REQUIREMENTS Tools and Parts Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools Location Requirements IMPORTANT: Observe all governing codes and ordinances.
Product Dimensions I H A E F G C B A. 3/8" (10 mm) B. 30" (76.2 cm) or 36" (91.4 cm) C. 26" (66.1 cm) D D. 2" (5.1 cm) or 5" (12.7 cm) E. 103/4" (27.4 cm) F. 3/4" (19 mm) Cabinet Dimensions A G. 117/8" (30.2 cm) or 177/8" (45.4 cm) H. 91/8" (23.1 cm) I. 135/8" (33.7 cm) * NOTE: 30" (76.2 cm) cabinet width can be 12" (30.5 cm) deep or 18" (45.7 cm) deep cabinets. 36" (91.4 cm) cabinet width requires 18" (45.7 cm) deep cabinets. For 18" (45.
Cold weather installations An additional back draft damper should be installed to minimize Example vent system: 6" (15.2 cm) 90˚ elbow to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break. The break should be as close as possible to where the vent system enters the heated portion of the house. Wall cap 6 ft (1.8 m) 3 ft (0.
Electrical Requirements WARNING Electrical Shock Hazard ■■ To minimize possible shock hazard, the cord must be plugged into a mating, 3 prong, grounding-type outlet, grounded in accordance with local codes and ordinances. If a mating outlet is not available, it is the personal responsibility and obligation of the customer to have the properly grounded outlet installed by a qualified electrician.
INSTALLATION INSTRUCTIONS Prepare Location ■■ It is recommended that the vent system be installed before the range hood is installed. ■■ Before making cutouts, make sure there is proper clearance within the ceiling or wall for vent fittings. Making the cutout to the bottom of the cabinet may be easier to do prior to mounting the cabinet to the wall. 1. Disconnect power. 2. Determine which venting method to use: roof, wall, or non‑vented. 3. Select a flat surface for assembling the range hood.
Transfer measurement A to the cabinet back wall. Measure from the underside of the cabinet. Mark the cutout as shown. Use a saber saw or keyhole saw to cut a round opening through the back of the cabinet and the exterior wall for Measure and mark the centerline location for the cutout in the cabinet top. Use a saber saw or keyhole saw to cut an opening for the vent. A B* Go to Step 3. C A D C B A. Measurement A B. Centerline C. 61/4" (15.
3. Install the vent system according to the method needed. Use caulking to seal the exterior wall or roof opening. Complete Preparation 1. If not yet attached, install the 6" (15.2 cm) vent transition the top of the range hood liner using two 3.5 x 9.5 mm screws. Install Range Hood WARNING Excessive Weight Hazard Use two or more people to move and install range hood. Failure to do so can result in back or other injury. 2.
4. Remove the metal grease filters from the face panel. See the “Range Hood Care” section. 5. Attach the face panel to the hood liner. (Three sizes: The 30" x 12" [76.2 cm x 30.5 cm] cabinet size is shown.) See instruction below for your specific cabinet size. Connect the Vent System Vented Installations 1. Connect the vent system to the range hood vent opening. Seal the connection with clamps. Non-Vented (recirculating) Installations C B Complete Installation 1. Replace grease filters.
RANGE HOOD USE The range hood is designed to remove smoke, cooking vapors, and odors from the cooktop area. For best results, start the hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from Range Hood Controls A The hood controls are located on the center of the front of the range hood liner. A. B. C. D.
Non-Vented (recirculating) Installation Filters with normal use. NOTE: When used in recirculation mode, To Reduce the Risk of Fire and Shock use only convertion kit Models: - Charcoal Filter Kit W10272068 - Recirculation Kit W10490330 To replace charcoal filter: 1. Cover the grille that covers the blower motor with the A B Turn off the range hood and allow the LED lamp to cool.
WIRING DIAGRAM SWITCH OPERATION MOTOR CHARACTERISTICS POWER SUPPLY 120 VA C FRECUENCY POWER ABSORTION BROWN -YELLOW (L-1) 240W LOW SPEED BROWN-WHITE (L-2) MED SPEED BROWN-BLUE (L-3) HIGH SPEED BROWN-BLACK (L-4) BU YL LAMPS BR 60H z WH NO CONNECTION BK OFF YL BLUE-BLACK 28.8 BLUE-GRE Y 30.3 BLUE-RED 37.7 BLUE-WHITE 45.1 ROOM TEMP. 23°C 73,4°F 4 5 BR YL BU BK 3 6 7 8 9 BK 2 WH YL/GN 1 YL/GN BR YL WH RD BK GR BU BU WH YL 12.
ASSISTANCE OR SERVICE If you need service In Canada Please refer to the warranty page in this manual. If you need replacement parts If you need to order replacement parts, we recommend that you use only factory specified parts. Factory specified parts will fit right and work right because they are made with the same precision used to build every new appliance.
LI30ZE/W11374536A ©2019 All rights reserved. Used under license in Canada. Tous droits réservés. Utilisé sous licence au Canada.