Installation Instructions

4
Cabinet Dimensions
NOTES: After making the countertop cutout, some installations
may require notching down the base cabinet side walls to clear
the cooktop base. To avoid this modication, use a base cabinet
with sidewalls wider than the cutout.
If cabinet has a drawer, a 4” (10.2 cm) depth clearance from the
countertop to the top of the drawer (or other obstruction) in base
cabinet is required. The drawer depth may need to be shortened
to avoid interfering with the regulator.
Electrical Requirements
IMPORTANT: The cooktop must be electrically grounded in
accordance with local codes and ordinances, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70
or Canadian Electrical Code, CSA C22.1.
This cooktop is equipped with an electronic ignition system
that will not operate if plugged into an outlet that is not properly
polarized.
If codes permit and a separate ground wire is used, it is
recommended that a qualied electrical installer determine
thatthe ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120-volt, 60 Hz., AC-only, 15-amp fused, electrical circuit
is required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this cooktop be provided.
Electronic ignition systems operate within wide voltage limits,
but proper grounding and polarity are necessary. Check that
the outlet provides 120-volt power and is correctly grounded.
The wiring diagrams are provided with this cooktop. See
“Wiring Diagrams” section.
B
D
A
C
E
F
H
I
J
G
K
L
M
J
A. 30” (76.2 cm) on 30” models; 36” (91.4 cm) on 36” models
B. Combustible area above countertop (shown by dashed box
above)
C. 30” (76.2 cm) minimum clearance between top of cooktop
platform and bottom of uncovered wood or metal cabinet
(24” [61 cm] minimum clearance if bottom of wood or metal
cabinet is covered by not less than ¹⁄
4
” [0.6 cm] flame retardant
millboard covered with not less than No. 28 MSG sheet steel,
0.015” [0.04 cm] stainless steel, or 0.024” [0.06 cm] aluminum
or 0.020” [0.05 cm] copper)
D. 15” (38.1 cm) maximum upper cabinet depth
E. 2¹⁄
8
” (5.4 cm)
F. 19” (48.3 cm)
G. 18” (45.7 cm) minimum clearance from upper cabinet to
countertop within minimum horizontal clearances to cooktop
H. Grounded outlet - locate within 24” (61 cm) of right rear corner
of cutout
I. 29” (73.7 cm) on 30” models; 35¼” (89.5 cm) on 36” models
J. 8³⁄
8
” (21.3 cm) minimum distance to nearest left and right side
combustible surface
K. 2
7
8
” (7.3 cm) minimum distance to rear combustible surface
L. Gas line opening - Wall: anywhere 5” (12.7 cm) below
underside of countertop. Cabinet floor: anywhere within 6”
(15.2 cm) of rear wall is recommended
M. 24” (61 cm) minimum countertop depth is required