Installation Instructions

5
Gas Supply Requirements
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest
edition.
IMPORTANT: Leak testing of the cooktop must be conducted
according to the manufacturer’s instructions.
Type of Gas
Natural Gas:
This cooktop is factory set for use with Natural gas. If
converting to Propane gas, see the following “Propane Gas
Conversion” section. The model/serial rating plate located
on the underside of the cooktop base has information on
the types of gas that can be used. If the types of gas listed
do not include the type of gas available, check with the local
gas supplier.
Propane Gas conversion:
Conversion must be done by a qualied service technician.
No attempt shall be made to convert the cooktop from the gas
specied on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier. See the Gas
Conversion instructions provided in the package containing
literature.
Gas Supply Line
Provide a gas supply line of
3
/
4
" (19 mm) rigid pipe to the
cooktop location. A smaller size pipe on longer runs may
result in insufcient gas supply. Pipe-joint compounds that
resist the action of Propane gas must be used. Do not
use TEFLON
®†
tape. With Propane gas, piping or tubing
size should be
1
/
2
" (13 mm) minimum. Usually, Propane
gas suppliers determine the size and materials used in the
system.
Flexible metal appliance connector:
If local codes permit, use a
1
/
2
" (13 mm) or
3
/
4
" (19mm)
I.D. exible stainless steel tubing gas connector,
designed by CSA to connect the cooktop to the rigid
gassupply line.
A
1
/
2
" (13 mm) male pipe thread is needed for connection
to the female pipe threads of the inlet tothecooktop
pressure regulator.
Do not kink or damage the exible metal tubing when
moving the cooktop.
Must include a shut-off valve:
Install a manual gas line shut-off valve in an easily accessible
location. Do not block access to shut-off valve. The valve is
for turning on or shutting off gas to the cooktop.
Gas Pressure Regulator
The gas pressure regulator supplied with this cooktop must be
used. The inlet pressure to the regulator should be as follows for
proper operation:
Natural Gas:
Minimum pressure: 5” (12.7 cm) WCP
Maximum pressure: 7” to 14” (17.8 cm to 35.5 cm) WCP
Propane Gas:
Minimum pressure: 11” (27.9 cm) WCP
Maximum pressure: 14” (35.5 cm) WCP
Contact local gas supplier if you are not sure about the
inletpressure.
Burner Input Requirements
Input ratings shown on the model/serial/rating plate are for
elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings are reduced at
a rate of 4% for each 1,000 ft (304.8 m) above sea level (not
applicable for Canada).
For elevations above 6,560 ft (1999.5 m) a high altitude kit
is needed to avoid any reduced power output. See separate
Propane gas conversion instructions sheet.
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least
1” (2.5 cm) water column pressure above the manifold pressure
shown on the model/serial rating plate.
Line pressure testing above
1
/
2
psi (3.5 kPa) gauge
14” (35.6cm)WCP
The cooktop and its individual shutoff valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of ½
psi (3.5 kPa).
Line pressure testing at
1
/
2
psi (3.5 kPa) gauge
14” (35.6cm)WCP or lower
The cooktop must be isolated from the gas supply piping
system by closing its individual manual shut-off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than
1
/
2
psi (3.5 kPa).
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A
B
C
A. Gas supply line
B. Shutoff valve “open” position
C. To cooktop
®
TEFLON is a registered trademark of Chemours.