Service Manual

Table Of Contents
DIAGNOSTICS & TROUBLESHOOTING
Whirlpool & Maytag Front-Load Dryers
n
2-11
Service Fault/Error Codes
Fault/Error Code Display Method
Fault codes are displayed by showing F#E#. The F# indicates
the suspect System/Category. The E# indicates the suspect
Component system.
The fault codes below may be indicated under various
condions and can be accessed through Service Diagnoscs.
Code Description Explanation and Recommended Procedure
F1E1
Motor or Heater Failure
or Connector Problem
Indicates no voltage detected at the heater relay.
Unplug dryer or disconnect power and check that the wires are plugged into the
heater element(s) and the relay(s) on the ACU.
For motor check, see Test #3: Motor Circuit, page 3-12.
F3E1
Exhaust Thermistor
Open/Shorted
Indicates that the exhaust thermistor is open or shorted. If the temperature drops
below 18° F (> 50k ohms), the exhaust thermistor is open. If the temperature is
above 250° F (< 500 ohms), the exhaust thermistor has shorted. May occur if the J14
connector is not plugged into the ACU. See TEST #4a: Thermistors, page 3-16.
F3E2
Moisture Sensor 1
Open/Shorted
Indicates the moisture sensor strip is open or shorted. This fault code will only appear
when in the service diagnosc mode. See TEST #5: Moisture Sensor, page 3-19.
F3E3
Inlet Thermistor Open/
Shorted
Indicates that the inlet thermistor is open or shorted. If the temperature drops below
18° F (> 245k ohms), the inlet thermistor is open. If the temperature is above 391° F
(< 328 ohms), the inlet thermistor has shorted. May occur if the J14 connector is not
plugged into the ACU. See TEST #4a: Thermistors, page 3-16.
F3E5
Moisture Sensor 2
Open/Shorted (only
Quad Sense models)
Indicates the second moisture sensor strip is open or shorted. This fault code will only
appear when in the service diagnosc mode. See TEST #5: Moisture Sensor, page 3-19.
F6E1
F6E2
ACU - HMI
Communic
aon Error
Indicates that the ACU and HMI have not communicated for a specied amount of
me.
Unplug dryer or disconnect power.
Check the harness connuity and connecons between the ACU and HMI.
Check AC and DC supplies. See TEST #1: ACU Power Check, page 3-8.
Replace the HMI.
Replace the ACU.
FCE1
WiFi Module
Communicaons Lost
Indicates that the WiFi Module has not responded for a specied amount of me.
Unplug dryer or disconnect power.
Check WiFi Module at HMI.
Replace HMI.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
Customer Diagnosc Codes
Code Description Explanation and Recommended Procedure
PF Power Failure PF indicates that a power failure occurred while the dryer was running.
Press START to connue the cycle, or press POWER to clear the display.
Console and LCD Fault Error Codes