Instruction manual

36
Furnace fails to
operate.
Integrated
control module
LED display
provides “b0
error code.
b0
Circulator
blower motor is
not running
when it should
be running.
Loose wiring
connection at
circulator motor
power leads or
circulator motor
power leads
disconnected.
Open circuit in
inductor or loose
wiring connection
at inductor (³⁄₄ Hp
and 1 Hp models
only).
Failed circulator
blower motor.
Tighten or correct
wiring connection.
Verify continuous
circuit through
inductor. Replace if
open or short circuit.
Check circulator
blower motor. Replace
if necessary.
Turn off power prior to
repair.
Replace inductor with
correct replacement
part.
Replace circulator
motor with correct
replacement part.
Furnace fails to
operate.
Integrated
control module
LED display
provides “b1
error code.
b1
Integrated
control module
has lost
communication
s with circulator
blower motor.
Loose wiring
connection at
circulator motor
control leads.
Failed circulator
blower motor.
Failed integrated
control module.
Tighten or correct
wiring connection.
Check circulator
blower motor. Replace
if necessary.
Check integrated
control module.
Replace if necessary.
Turn off power prior to
repair.
Replace circulator
motor with correct
replacement part.
Replace integrated
control module with
correct replacement
part.
Furnace fails to
operate.
Integrated
control module
LED display
provides “b2
error code.
b2
Circulator
blower motor
horse power in
shared data set
does not match
circulator
blower motor
horse power.
Incorrect circulator
blower motor in
furnace.
Incorrect shared
data set in
integrated control
module.
Verify circulator blower
motor horse power is
the same specified for
the specific furnace
model. Replace if
necessary.
Verify shared data set
is correct for the
specific model.
Repopulate data using
correct memory card, if
required.
Turn off power prior to
repair.
Replace motor with
correct replacement
part.
Use memory card for
the specific model.
Insert memory card
before turning on
power. Memory card
may be removed after
data is loaded.
Turn off power before
removing memory
card.
Error code will be
cleared once shared
data and motor horse
power match.
Furnace
operates at
reduced
performance.
Airflow
delivered is less
than expected.
Integrated
control module
LED display
provides “b3
error code.
b3
Circulator
blower motor is
operating in a
power,
temperature or
speed limiting
condition.
Blocked filters.
Restrictive
ductwork.
Undersized
ductwork.
High ambient
temperatures.
Check filters for
blockage. Clean filters
or remove obstruction.
Check ductwork for
blockage. Remove
obstruction. Verify all
registers are fully open.
Verify ductwork is
appropriately sized for
system. Resize/replace
ductwork if necessary.
See “Product
Description” and
“Location
Requirements and
Considerations” for
furnace installation
requirements.
Turn off power prior to
repair.
Symptoms of
Abnormal
Operation
Diagnostic/
Status LED
Code Fault Description Possible Causes Corrective Actions Notes and Cautions