Installation Instructions

15
To Convert Gas Pressure Regulator
1. Open broiler door and remove broiler rack. The gas pressure
regulator is located in the back right hand corner of the broiler
compartment.
IMPORTANT: Do not remove the gas pressure regulator.
NOTE: Do not remove the spring beneath the cap.
2. Remove the cap from the gas pressure regulator using a
flat-blade screwdriver.
NOTE: Make sure sealing washer remains in the same
position.
3. To convert to Natural gas, unscrew the plastic adjustment
screw by hand, turn it over, and screw it in again.
4. Reinstall the cap.
To Convert Surface Burners
1. Remove burner grate, burner caps and burners.
2. Locate the Natural gas orifice spuds for top burners in the
bag containing literature included with the range. Two Natural
gas spuds are stamped “194 (Black/White),” one is stamped
“155 (Red/Brown),” one is stamped “140 (Red/White)” and
one is stamped “110 (Red/Brass).”
3. Remove the LP gas orifice spuds using a 7 mm (⁹⁄₃₂")
combination wrench.
4. Install the Natural gas orifice spuds using a 7 mm (⁹⁄₃₂")
combination wrench.
A. Gas pressure regulator
A. Cap
Inlet pressure
to LP gas
Inlet pressure
to Natural gas
A. Cap
B. Sealing washer
C. Adjustment screw
A
A
C
A
B
180
º
A. Burner cap
B. Burner
C. Center burner
A. Spud
B. Holder
A
B
C
A
B