Specifications

Page 4 | 1-855-235-5271
WM&FD 021014
DUCTED FD UNIT SPECIFICATIONS
Model
3500 Evaporator
(Fan Coil Unit)
3500 Condenser
(Air Cooled
Condensing Unit)
5000 Evaporator
(Fan Coil Unit)
5000 Condenser
(Air Cooled
Condensing Unit)
Cellar Size (cu. ft.) 1000 2000
Dimensions 20.5”w x 15.625”h x 20”d 12”w x 13.5”h x 18”d 20.5”w x 15.625”h x 20”d 12”w x 13.5”h x 18”d
BTUh with 90° air entering
the Condenser Coil
3120 3788
CFM
200 190 200 350
Refrigerant R-134a
HP 1/3++ 1/2
Voltage Rating
(20
amp dedicated circuit
required)
115V or 230V
Weight (lbs) 56 56 56 66
AMPS
(Starting/Running) 2/1 32.7/7.2 2/1 48/9.5
dBA 54 65 54 65
Drain Line 1/2” Condensate
Installation Use 8” supply and 10” return insulated ducting. Ducting should not exceed 25 ft. from the cellar.
Thermostat Optional Digital Remote Display
Temp. Delta 55°F
Temperature dierential between the cellar temperature and condenser intake air temperature.
Warranty 2 year parts and labor
°
F
QUICK REFERENCE GUIDE
FD Evaporator Unit (Fan Coil Unit) Front / Side View
Keypad
Duct Plenum
Return Air
Supply Air