Manual

REPLACING AN IONIZING WIRE
If one or more ionizing wires in the cell should break,
usually caused by accidental damage, it can be replaced as
follows:
1. Remove all pieces of broken wire. Make sure supports
at each end are in good condition and not bent out of
shape.
2. Hook the wire at one end onto the support.
3. Hold a finger against the support at other end (Figure
25) and hold ionizing wire between thumb and
forefinger as shown. Press on spring and push on wire
loop until it slips over end of support. Make sure wire
is securely anchored at each end.
Figure 25
Service hints...
"The following instructions are for use by qualified personnel, WARNING: The
following procedures will expose hazardous live parts. Disconnect electrical
power to aircleaner before proceeding."
INDICATION
ON-OFF Switch Light on 1.
-Operating Light on.
ON-OFF Switch Light off 1.
-Operating Light off.
1.
ON-OFF Switch Light on
-Operating Light off.
2.
3.
CORRECTIVE PROCEDURES
Electric power is being supplied to the air cleaner
and the unit is functioning.
Electric power is not being supplied to the air cleaner.
a. See that system fan is operating.
b. Check fuse or circuit breaker in main circuit control box.
c. Check ON-OFF switch for ON position.
Large foreign object mig.ht be lodged between collective plate of cell.
a. Remove cell and wash throughly.
Broken ionizing wire.
a. Install a new wire as outlined above.
Malfunction in electric power supply.
a. Notify your Service Man.
11