Whynter 62 QT DUAL ZONE PORTABLE FRIDGE / FREEZER MODEL# : FM-62DZ Instruction Manual Congratulations on your new WHYNTER product. To ensure proper operation, please read this Instruction Manual carefully before using this product. Keep this manual in a safe place for future reference.
TABLE OF CONTENTS SAFETY PRECAUTIONS…….……………………………………..……………….....3 PARTS AND FEATURES.…………………………………………………………….. 4 PROPER LOCATION……………………………………………………………………5 MOVEMENT AND INSTALLATION INSTRUCTIONS……………………….………5 OPERATING YOUR PORTABLE FREEZER..…………………………….……… 6-8 TEST-RUN……………………………………………………………………………….6 UNDERSTANDING THE TEMPERATURE CONTROL SETTING………………...6 TEMPERATURE ADJUSTMNET……………………………………….……………..7 FOOD STORAGE……………………………………………………………………….7 DEFROSTING AND DE-ODERIZING………………………………………………...
SAFETY PRECAUTIONS Read all of the instructions before using this appliance. When using this appliance, always exercise basic safety precautions, including the following: Do not use if the power supply cord is damaged. If damaged, it must be replaced by qualified technician/electrician. This portable freezer is not intended for use by young children or infirm persons without supervision.
PARTS AND FEATURES Your Whynter portable freezer is supplied with all the accessories you need to enjoy refrigeration almost anywhere. Below is an image of the freezer features and standard accessories. 1. Latch 2. Insulated lids 3. Wire baskets 4. Side handle 5. DC power cord 6. AC power cord 7. Drain plug If you want to protect and provide additional insulation for your Whynter portable freezer, the Whynter insulated flexible transit bag is your best solution.
Proper Location Because this unit is Position your portable freezer in a location where there is compressor based proper air circulation and electrical connections. appliance, ample Keep the portable freezer away from heat and direct space is required sunlight if possible. around the unit to This portable freezer is suitable for vehicle use and allow it to exhaust camping however, the appliance should never be properly. exposed to rain.
OPERATING YOUR PORTABLE FREEZER Test-Run DC input power When powering your portable freezer with a standard 12 V socket, the unit will not work if socket has a voltage of less than 10.4 V. The unit will restart when the voltage is 11.8V or greater. When powering your portable freezer into a standard 24 V socket, the unit will not work if the socket has a voltage of less than 22.5 V. The unit will restart when the voltage is 24.2 V or greater.
Temperature Adjustment 1. When the freezer is plugged in to a power outlet, press the “Set” button. The LED will display the factory pre-set temperature of 0°F 2. To adjust the temperature: a. Press the “Set” button again b. While the LED is flashing, press the “▲” or “▼” buttons to reach the desired temperature c. Once the desired temperature is set, the LED stops flashing. The current internal temperature will then be displayed.
Normal Operating Sounds and Functions It is normal to hear gurgling sounds caused by the flow of refrigerant when each cooling cycle ends. The surface temperature of the compressor can reach 158-194°F when running. The noise emitted by the cooling fan on the condenser is a normal function. It is normal for the fan in the power supply to run all the time. CLEANING YOUR PORTABLE FREEZER Always disconnect the power supply before cleaning.
TROUBLESHOOTING Problem Cause The compressor runs for 1 to 5 The voltage is not in the minutes and stops. correct range. The ambient temperature The compressor runs but the is too high. inner liner does not get very cold. The system is blocked. The inner liner is very cold and the compressor runs continuously. The compressor does not run. The freezer is noisy. The ice layer on the evaporator is too thick. The door is being opened and closed too frequently. The freezer is overloaded.
ONE YEAR LIMITED WARRANTY This WHYNTER Portable Fridge/ Freezer is warranted, to the original owner within the 48 continental states, for one year from the date of purchase against defects in material and workmanship under normal use and service.