SDS

Page 8 of 15
produced at
low levels where general ventilation is poor.
In such cases, provide adequate ventilation or wear suitable
respiratory protective equipment with positive air supply.
Avoid contact between the liquid and skin and eyes.
Use only properly specified equipment which is suitable for this
product, its supply pressure and temperature.
Suck back of water into the container must be prevented.
Do not allow back feed into the container.
Contact your gas supplier if in doubt.
Never use direct flame or electrical heating devices to raise the
pressure of cylinder.
Valve protection caps must remain in place unless container is
secured with valve outlet piped to use point.
Do not drag, slide or roll cylinders.
Use a suitable hand truck for cylinder movement.
Use a check valve or trap in the discharge line to prevent
hazardous back flow into the cylinder.
Use a pressure regulator when connecting cylinder to lower
pressure piping or systems.
Avoid venting to atmosphere.
Condition for safe storage
Keep away from ignition sources (including static discharges).
Do not allow the temperature where cylinders are stored to
exceed 125
o
F (52
0
C).
Use a “first-in-first out” inventory system to prevent full
cylinders from being stored for excessive period of time.
Store in cool, dry, well-ventilated area of non-combustible
construction away from heavily trafficked areas and emergency
7. HANDLING AND STORAGE
Precaution for safe handling
Avoid inhalation of high concentrations of vapors.
Atmospheric level should be controlled in compliance with the
occupational exposure limit. Atmospheric concentrations well
below the occupational exposure limit can be achieved by good
occupational hygiene practice.
The vapor is heavier than air, high concentrations may be
exits
Full and empty cylinders should be segregated.
Containers should not be stored in conditions likely to
encourage corrosion.
Container should be stored in the vertical position and properly
secured to prevent falling over.
Outside or detached storage is preferred.
Post “No Smoking” signs in use or storage areas.
There should be no accidental ignition in areas where this
product is being used or stored.
Avoid storing near to the intake of air conditioning units, boiler
units, and open drains.
Electrical installations / working materials must comply with
the technological safety standards.
Do not store with oxidizers.