Specification

571210-CTG-C-1012
Johnson Controls Unitary Products 15
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during
the same period.
MA Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
— = Not Applicable.
HEATING CAPACITY - Upflow, Downflow, and Horizontal Furnaces and Coils (Coil Only Ratings)
UNIT
MODEL
COIL
1
MODEL
HEATING
2
47 F 17 F HSPF
MBH COP KW MBH COP KW STD
13 SEER HP COIL ONLY RATINGS
THJD18S41S3
FC/MC/PC18 18.0 3.36 1.50 12.7 2.16 1.24 8.20
FC/MC/PC24 18.0 3.36 1.45 10.4 2.60 1.17 8.20
FC/MC/PC30 18.0 3.42 1.54 11.4 2.18 1.53 7.75
UC24 18.0 3.42 1.54 11.4 2.20 1.52 7.75
UC30 18.0 3.42 1.54 11.4 2.20 1.52 7.75
THJD24S41S4
FC/MC/PC32 24.0 3.36 2.09 13.9 2.38 1.71 7.70
FC/MC/PC35 23.8 3.32 2.10 13.9 2.36 1.73 7.70
FC/MC/PC37 24.0 3.44 2.04 14.1 2.42 1.71 7.70
FC/MC/PC43 24.0 3.44 2.04 14.1 2.42 1.71 7.70
THJD30S41S4
FC/MC/PC32 27.4 3.28 2.45 16.0 2.30 2.04 7.70
FC/MC/PC35 27.4 3.28 2.45 16.0 2.30 2.04 7.70
FC/MC/PC37 28.0 3.38 2.43 16.1 2.32 2.03 7.70
FC/MC/PC43 28.0 3.38 2.43 16.1 2.32 2.03 7.70
THJD36S41S4
FC/MC/PC37 34.4 3.42 2.95 22.4 2.62 2.51 7.70
FC/MC/PC43 34.6 3.40 2.98 22.2 2.60 2.50 7.70
FC/MC/PC48 34.8 3.44 2.96 22.6 2.64 2.51 7.70
UC48 35.0 3.52 2.91 22.4 2.62 2.51 7.70
THJD42S41S4
FC/MC/PC60 40.5 3.72 3.19 23.0 2.50 2.70 7.70
UC60 40.0 3.68 3.18 22.8 2.48 2.69 7.70
THJD48S41S4
FC/MC/PC60 46.0 3.58 3.76 27.4 2.76 2.91 7.70
FC/MC62 46.0 3.54 3.81 27.4 2.76 2.91 7.70
UC60 46.0 3.56 3.79 27.4 2.74 2.93 7.70
THJD60S41S5
FC/MC62 58.0 3.44 5.24 39.5 2.66 4.35 7.80
FC64 58.03.365.4940.52.764.307.80
1. Rated CFM same as for cooling.
2. Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping and
no supplemental electric heat operation.