Specification

571210-CTG-C-1012
36 Johnson Controls Unitary Products
Multipliers for determining the performance with other indoor sections.
Continued on next page.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO THJD18S41S3
EVAPORATOR COIL MODEL NO FC35
AIR TEMP.
ENTERING
OUTDOOR UNIT
AIR TEMP.
ENTERING
INDOOR COIL
ID CFM
450 600 750
MBH COP KW MBH COP KW MBH COP KW
60
60 21.1 4.1 1.50 22.2 4.5 1.44 23.3 4.9 1.39
70 20.5 3.6 1.65 21.6 4.0 1.59 22.6 4.3 1.53
80 19.9 3.2 1.81 20.9 3.5 1.74 21.9 3.9 1.66
47
60 18.6 3.8 1.45 19.2 4.0 1.41 19.8 4.2 1.38
70 17.7 3.3 1.60 18.4 3.5 1.55 19.1 3.7 1.51
80 16.8 2.8 1.74 17.6 3.1 1.69 18.4 3.3 1.64
40
60 16.7 3.4 1.43 17.3 3.6 1.40 17.9 3.8 1.37
70 16.1 3.0 1.57 16.8 3.2 1.53 17.4 3.4 1.50
80 15.6 2.7 1.70 16.3 2.9 1.66 17.0 3.1 1.62
30
60 14.6 3.1 1.39 15.1 3.2 1.37 15.5 3.4 1.36
70 14.2 2.7 1.52 14.6 2.9 1.50 15.0 3.0 1.48
80 13.7 2.4 1.66 14.1 2.5 1.63 14.4 2.6 1.61
17
60 11.7 2.6 1.34 12.0 2.6 1.34 12.3 2.7 1.34
70 11.2 2.2 1.48 11.6 2.3 1.47 11.9 2.4 1.46
80 10.8 2.0 1.62 11.1 2.0 1.60 11.5 2.1 1.58
10
60 10.1 2.3 1.31 10.3 2.3 1.31 10.4 2.3 1.32
70 9.6 1.9 1.45 9.9 2.0 1.44 10.2 2.1 1.44
80 9.1 1.7 1.59 9.5 1.8 1.58 9.9 1.9 1.57
NOTE: ALL CAPACITIES ARE NET, WITH INDOOR FAN HEAT ALREADY DEDUCTED. KW VALUES ARE FOR THE SYSTEM (OUTDOOR + INDOOR).
Air Handlers Coils MBH COP KW
FC/MC/PC18 1.05 0.94 1.13
FC/MC/PC24 1.06 0.98 1.08
FC/MC/PC30 1.06 0.98 1.08
UC24 1.05 0.98 1.08
UC30 1.05 0.98 1.08
AHE18B 1.03 1.01 1.02
AHR18B 1.05 0.97 1.09
AHV18B 1.03 1.00 1.03
AV*24 1.03 1.03 1.00
MV12B FC/MC/PC18B 1.03 1.01 1.02
MV12B FC/MC24B 1.04 1.03 1.00
MV12B FC/MC30B 1.04 1.03 1.00
MX12B FC/MC/PC18B 1.03 1.01 1.02
MX12B FC/MC24B 1.03 1.08 0.96
MX12B FC/MC30B 1.03 1.08 0.96