Spec Sheet

SP-110/H PG 2
ELECTRICAL
VOLTS
LP NG
MAIN CBWATTS KVA AMPS WATTS KVA AMPS
120/240 1-PH 17,000 17 71 15,000 15 62 80
SPECIFICATIONS
ENGINE BRAND BRIGGS & STRATTON
ENGINE MODEL VANGUARD
ENGINE STARTER ELECTRIC
ENGINE SPEED 3600 RPM
ENGINE CYLINDERS V-TWIN
GOVERNOR MECHANICAL
DISPLACEMENT/TYPE 993 CC / OHV
FREQUENCY REGULATION
(1)
+/- 5%
LOW OIL PROTECTION STANDARD
RECOMMENDED OIL
(2)
10W-30
OIL CAPACITY 2.5 QT
EXHAUST CRITICAL GRADE
NOTES: (1) Steady state frequency regulation. (2) The recommended oil is for
normal applications. See operator’s manual for the recommended oil for your
needs.
ENGINE
MOTOR STARTING (CODE G) 5 HP
DBA @ 7 METERS
NO LOAD
FULL LOAD
65.1
76.3
TOTAL HARMONIC DISTORTION < 5%
ASSEMBLED IN USA
EPA APPROVED YES
CARB APPROVED YES
TÜV CERTIFICATION UL2200
CSA
UNIT WARRANTY
(1)
2 YEARS/2000 HRS
NOTES: (1) For more generator warranty, see operator’s manual.
GENSET
VOLTAGE REGULATION AVR +/- 1%
TEMPERATURE RISE 125/40° C
TYPE REVOLVING FIELD
BRUSHLESS YES
SPEED 3600 RPM
ROTOR 2/3 PITCH
WINDINGS 100% COPPER
COUPLING DIRECT/MOTOR SHAFT
BEARINGS SINGLE
(MAINTENANCE FREE)
INSULATION CLASS H
INGRESS PROTECTION IP23
GENERATOR END
DC SYSTEM 12V
BATTERY RACK/CABLE INCLUDED
BATTERY CHARGER 1.5 AMP
REQUIRED BATTERY
(1)
GROUP 26 500 CCA
NOTES: (1) Battery not included.
BATTERY
ABOVE SEA LEVEL 3% PER 1640 FT
MAX OPERATING
TEMPERATURE
122°F
3% PER 10°F > 104°F
DERATES
INLET PRESSURE 4-6 OZ/7-11” WATER COLUMN
FUEL INLET SIZE 3/4"
FUEL CONSUMPTION LP
100% 3.61 GAL/HR - 329,000 BTU/HR
FUEL CONSUMPTION NG
100%
328 FT³/HR - 328,000 BTU/HR
FUEL
Specifications are subject to change without notice.