- Spencer Installing and Operating Instructions Vacuum Cleaning Systems A,B,C, D ,V

3
Location
Industravac vacuum producers are designed for operation at or
near sea level atmospheric pressure and a nominal ambient
temperature of 70°F (21°C).When necessary, they can be factory-
designed for higher altitude or higher temperature operation.
Consideration should be given to the noise generated by
Industravac equipment and its contribution to the ambient
noise level. When desired, the exhaust can be fitted with an
optional Spencer silencer. C Series models have a built-in
silencer as standard equipment.
Note: V Series stationary models should be properly protected
from precipitation.
Portable Model. The portable Industravac unit is designed for
use on flat, dry, level surfaces. As a safety precaution, the
wheels should be blocked to prevent accidental movement.
Typical Industravac Assembly
Filter Bag Buckle
External
Bag Shaker
Access Door
Inverted
Filter Bags
Adjustable
Door Latches
Vacuum
Tube Inlet
Target Plate
Patent No. 4,874,410
Optional
Equilizing Line
Dirt Can
Locking Bail
Dirt Can
Lift Cam Cam Arm
Lever Clamp
Bag Head Spring
Two-Stage
Separator
Multi-Stage Centrifugal
Vacuum Producer
(Series A, B & D)
Impellers
and Deflectors
Exhaust
Outlet
Spencer
Reverse-Curve Casing
Registered Trademark No. 1,616,417
Continuous
Duty Motor
Connector Sleeve
and Clamps
Vacuum Inlet Valve for
1-1/2" I.D. Hose (Standard)
Steel Frame