Installation guide

7
2.4 Installing the ducts
The connections must be sealed to prevent condensation forming on the walls
o
f the air-conditioner.
2.4 Installing the water flue
The connections must be sealed to prevent condensation forming on the walls
of the air-conditioner.
1. Place the inside duct
on the flue collar
2. Stick the adhesive tape across
the flue collar and the duct.
3. Take it round several times
to ensure a good seal.
4. Position the insulation duct,
then the ring clamp
5. Close the head of the ring clamp
after tightening it manually.
6. Screw up the ring clamp and
repeat the operation on the
other flue collar.
1. Screw the bend, supplied with
the equipment, on the right side
of the device.
2. Slide on the PVC tubing. 3. Connect the free end of the PVC
tubing to a wastewater point or
retention tank.
Avoid ‘counter-slopes or ‘siphons
IMPORTANT
Wait for 24 hours before switching the air-conditioner on.