How-To Guide Part 3

6 Troubleshooting84
02D0 System cache error -
Cache disabled
RAM cache failed and BIOS disabled the cache. On older
boards, check the cache jumpers. You may have to
replace the cache. See your dealer. A disabled cache
slows system performance considerably.
02F0: CPU ID: CPU socket number for Multi-Processor error.
02F4: EISA CMOS not
writeable*
ServerBIOS2 test error: Cannot write to EISA CMOS.
02F5: DMA Test Failed* ServerBIOS2 test error: Cannot write to extended DMA
(Direct Memory Access) registers.
02F6: Software NMI
Failed*
ServerBIOS2 test error: Cannot generate software NMI
(Non-Maskable Interrupt).
02F7: Fail-Safe Timer NMI
Failed*
ServerBIOS2 test error: Fail-Safe Timer takes too long.
device Address Conflict Address conflict for specified device.
Allocation Error for: device Run ISA or EISA Configuration Utility to resolve
resource conflict for the specified device.
Failing Bits: nnnn* The hex number nnnn is a map of the bits at the RAM
address which failed the memory test. Each 1 (one) in the
map indicates a failed bit. See errors 230, 231, or 232
above for offset address of the failure in System,
Extended, or Shadow memory.
Invalid System
Configuration Data
Problem with NVRAM (CMOS) data.
I/O device IRQ conflict I/O device IRQ conflict error.
One or more I2O Block
Storage Devices were
excluded from the Setup
Boot Menu
There was not enough room in the IPL table to display all
installed I2O block-storage devices.
Operating system not found Operating system cannot be located on either drive A: or
drive C:. Enter Setup and see if fixed disk and drive A:
are properly identified.
Error Messages Corrective Action