User manual

14
Display
This menu allows to configure display setting
PARAMETER
SETTING
MEANING
LED
Full
Alarm
OFF
3 LED setting are available:
Full: LED indicators works normally
Alarm: LED indicators lights up only when an alarm
happened
OFF: LED indicators remain off
Contrast
0÷5
Change contrast display from 0 (min) to 5 (max).
Low timeout
(sec)
5÷60
(5sec. steps)
Low timeout sets the timeout from 5 to 60 seconds
(5sec steps) to decrease the brightness display.
Off timeout (sec)
10÷120
(10sec. steps)
/ OFF
Off timeout sets the timeout from 10 to 120 seconds in
10 sec. steps to turn off the display. With OFF setting
the display never turns off.
Infrared menu
By this menu, MPR30-IEM can be connected to IRDA for setup or firmware upgrades.
When the Infrared interface is active, the following screen is displayed.
NOTE: while in this menu display is not automatically turned off.
Sync menu
The SYNC function is useful to tune a transmitter
on the same frequency of the receiver via the IR
interface. Before starting the sync function tune the
receiver on desired channel, manually or using the
SCAN utility. After this, enable the IR interface on
the transmitter. Now press UP&EXIT buttons together
or enter in the Sync menu to start the SYNC function. Keep the IR window of the transmitter in
front of the IR window of the receiver and, as soon as the connection is done, the receiver will
send to the transmitter all the information needed.
If the operation is not possible, (i.e. the frequency range of the transmitter is not
compatible with the frequency of the receiver), the display will show an error message.
If the transmitter has the function “NAME” enabled, when the sync function is completed it
will show the same name of the synchronized receiver.