User manual

16
ERROR LIST
When an error occurs, the receiver
A. shows a message on the display
and for some error types
B. increases the errors counter in the info menu
C. inserts the error type and code on the error list in the info menu
When the error is solved, the message on the display disappear, but the error information
(code and description) are available on the error list in the Info menu (only for some error, see
the below table).
NOTE
1
: When the receiver is reset the error information (code and error type on the list) are
lost, with the exception of errors codes 87/88/89/8A.
NOTE
2
: To reset the error counter and the errors list, it is necessary to contact Wisycom.
Errors
Message on display
(A)
Error type
(C)
Code
(C)
HW init failed
HW init failed
Battery Low
Battery Low
Battery charge failed
Battery charge failed
I2C communication error
I2C communication error
I2C access failed
04
Device ID copy1 invalid
Memory recovered
Device ID copy1 invalid
Memory recovered
Device ID copy 1
87
Device ID copy2 invalid
Memory recovered
Device ID copy2 invalid
Memory recovered
Device ID copy 2
88
RF copy1 invalid
Memory recovered
RF copy1 invalid
Memory recovered
RF mem copy 1
89
RF copy2 invalid
Memory recovered
RF copy2 invalid
Memory recovered
RF mem copy 2
8A
PLL unlocked
-
PLL unlocked
84
CH mem header
-
CH mem header
85
Param mem header
-
Param mem header
86