Inc GAS COOK TOPS INSTALLATION INSTRUCTIONS

9
Dimensions in parentheses are in
millimeters unless otherwise specified.
INSTALLATION INSTRUCTIONS
VENTILATION OPTIONS
IMPORTANT NOTE:
It is recommended that
you operate the Wolf gas cooktop with either a
W
olf cooktop ventilation hood, downdraft
system or Pro ventilation hood. Contact your
Wolf dealer for details.
Cooktop Wall Hood –
30" (762) or 36" (914)
w
idths in classic stainless steel.
Cooktop Island Hood –
42" (1067) width in
classic stainless steel.
Downdraft Ventilation System –
30" (762),
36" (914) or 45" (1143) widths, with top
cover and control panel in classic, platinum
and carbon stainless steel finishes (45"
downdraft available in classic finish only).
Pro Wall Hood –
22" (559), 24" (610) or 27"
(686) depths and 30" (762) to 66" (1676)
widths in classic stainless steel.
Pro Island Hood –
36" (914) to 66" (1676)
widths in classic stainless steel.
Pro Hood Liner –
available in widths to
accommodate 30" (762) to 60" (1524) hood
shells.
All hoods have welded seams, sealed halogen
lighting and removable, dishwasher-safe
filters.
Blower requirements may vary due to the
length of ducting and number of angles. The
basic r
ecommendation is 1 CFM per 100 Btu/hr
(.03 kW). Always consult your HVAC profes-
sional for mor
e concise blower requirements.
IMPORTANT NOTE:
When installing a ventila-
tion hood, refer to the specific requirements
of the hood for the minimum dimension to
countertop.
INSTALLATION OPTIONS
MULTIPLE COOKTOP INSTALLATION
I
f the gas cooktop is to be used with any
combination of additional cooktop units or
modules with a filler strip, the cut-out width is
c
alculated by adding the corresponding units'
cut-out dimensions plus 1
1
/4" (32) for each
additional unit. Refer to the illustration below.
IMPORTANT NOTE:
When multiple units are
installed side by side, each unit must have its
own separate recommended electrical circuit.
When multiple gas units are installed next to
one another, they can receive their gas supply
from a common line. However, each unit
MUST
have its own regulator installed
between the mainline and the gas cooktop.
When two or more modules are installed
together, an integrated module filler strip
(IFILLER/S) is recommended. If a downdraft
ventilation system is also installed, an inte-
grated module support for downdraft ventila-
tion (ISUPPORT) is also required (Model DD30
only). Contact your Wolf dealer for information
on these accessory components.
Countertop cut-out dimensions for installation of multiple cooktops
OPTIONAL
INSTALLATIONS
Dimensions will
vary according to
the specific
installation.