ELECTRICAL REQUIREMENTS
Installation must comply with all applicable electrical codes.
Locate the electrical supply as shown in the illustrations
on the following pages. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption
of operation. Refer to the illustration below for minimum
power cord plug clearance.
Performance may be compromised if the electrical supply
is less than 240 volts.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 20 amp dedicated circuit
Receptacle NEMA 6-20R grounding-type
Power Cord 6' (1.8 m)
Planning Information
The Convection Steam Oven can be installed in a standard
or flush inset application.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, the face trim will overlap stiles
and rails. Refer to the chart below.
For flush inset installations, a minimum ⁄"
(3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
Convection Steam Oven 100 lb (45 kg)
TRIM OVERLAP 24" MODEL 30" MODEL
Top ⁄" (5) ⁄" (5)
Bottom 0" (0) 0" (0)
Sides ⁄" (18) 3⁄" (98)
1" (25)
MINIMUM
CORD
CLEARANCE
Power cord clearance
Convection Steam Ovens