Power Supply Operating Manual 42V 10A

Specification
OUTPUT
Voltage Range: 0V to 42V minimum
Current Range: 0A to 10A minimum
Output Voltage Setting: By coarse and fine controls.
Output Current Setting: By single logarithmic control.
Operating Mode: Constant voltage or constant current with automatic cross-over.
Output Switch: Electronic. Preset voltage and current displayed when off.
Output Terminals: 4mm terminals on 19mm (0.75”) pitch.
Output Impedance:
Typically <5m in constant voltage mode.
Typically >20k in constant current mode.
Output Protection: Output will withstand up to 48V forward voltage.
Reverse protection by diode clamp for reverse currents up to 3A.
Over-temperature
Protection:
The output will be tripped off if a fault causes the internal
temperature to rise excessively.
Load & Line Regulation: <0.01% of maximum output for a 90% load change or 10% line
change.
Ripple & Noise
(20MHz bandwidth):
Typically <2mVrms, <10mV pk-pk, constant voltage mode.
Transient Response: <200µs to within 50mV of set level for 90% load change.
Temperature Coefficient: Typically <100ppm/°C
Status Indication: Output on lamp. Constant current mode lamp.
METER SPECIFICATIONS
Meter Types: Dual 4 digit meters with 14mm (0.56") LEDs. Reading rate 4 Hz.
Meter Resolutions: 10mV, 10mA
Meter Accuracies: Voltage 0.3% of reading ± 2digit,
Current 0.6% of reading ± 2digit
GENERAL
AC Input: Factory set for: 110V - 120V AC ±10% or 220V - 240V AC ±10%,
50/60Hz. Installation Category II.
Power Consumption: 800VA max.
Operating Range: +5ºC to +40ºC, 20% to 80% RH.
Storage Range:
40ºC to + 70ºC.
Environmental: Indoor use at altitudes up to 2000m, Pollution Degree 2.
Safety:
Complies with EN610101.
EMC: Complies with EN61326.
Size: 140 x 160 x 320mm (WxHxD).
Weight: 3.6kg
3