Manual

50 Truecharge2 Series Battery Charger Owner’s Guide
Troubleshooting
In the event that you have a problem with your Truecharge2 Battery
Charger, the following tables will help you to identify the problem and offer
possible solutions to the problem.
Symptom
Indicator LEDs do not illuminate when charger is connected to an AC
power source.
Symptom
The initial power up display test is not performed upon connection of
battery or batteries.
Possible Cause Solution
No power at AC source
Defective AC wiring or
switches/breakers
Remote panel has been used to
put the charger into Standby
mode.
Ensure that power is available at
charger AC input and it is within
acceptable range.
Wiring must be inspected and replaced
by a qualified installer.
Press the On/Standby button on the
remote panel to turn the charger on.
Possible Cause Solution
Truecharge2 Battery Charger
does not detect battery for one of
the following reasons:
poor connection
reverse polarity connection
(blown fuse)
damaged wiring
open DC breaker or external
fuse
battery voltage is below 9 V
Check quality of battery connection and
wires.
Ensure correct polarity (negative
connected to negative, positive
connected to positive).
In case there is an accompanying fault,
check the type of fault from
“Interpreting Fault and Warning
Indicators” on page 43.
TC2 204060 Series BattChg Owners Guide.book Page 50 Friday, July 8, 2011 11:44 AM