Appendix D. Hardware Specifications
98 iX104 User’s Handbook
Environmental specifications
Temperature Operating:
-4
o
to 140
o
F (-20
o
to 60
o
C)
•Storage:
-40
o
to 167
o
F (-40
o
to 75
o
C)
Humidity 0% to 95% non-condensing
Shock/Drop Three-foot drop to concrete, all surfaces, edges
and corners
Vibration 0.04g^2/Hz, 20 Hz - 1000 Hz
-6dB/octive 1000 Hz - 2000 Hz
Enclosure Class Blowing rain:
4”/hr, 40 mph wind and
MIL-STD-810F Method 506.4 Procedure 1
Drip:
7 gal/ft2/hr
MIL-STD-810F Method 506.4 Procedure III
Sand and dust:
Particle size < 149 µm, 10 +
7 g/m3 particle
density 1.5 m/s to 8.9 m/s wind speed
MIL-STD-810F Method 510.4 Procedure 1
Salt Fog:
5% saline for 48 hr (12 hr wet, 12 hr dry,
2 cycles)
MIL-STD-810F Method 509.4
Contamination by fluids:
Detergents, brake fluid, aromatic hydrocarbons
MIL-STD-810F Method 504
Solar radiation:
1120 W/m2 (355 Btu/ft2/hr) UVB @ 50° C,
7x24 hr cycles
MIL-STD-810F Method 505.4