Sun SPARC Enterprise M8000/M9000 Servers Product Notes 7
TABLE 4 XCP Issues and Workarounds
ID Description Workaround
6565422 The Latest communication field in
showarchiving is not updated regularly.
Disabling and re-enabling archiving refreshes
the Latest communication field in
showarchiving output.
6575425 Most XSCF commands should display
“Permission denied” when they are executed
on the Standby XSCF. Instead, some
commands report various errors.
Only the following commands can be executed
on the Standby XSCF: snapshot, switchscf
Do not attempt to run any other command on
the Standby XSCF.
6588650 On occasion, the system is unable to DR after
an XSCF failover to or from backup XSCF.
There is no workaround.
6624646 Sun Connection Update Manager GUI might
fail to register correctly.
Use the command-line interface (CLI) if you run
into any GUI registration issues.
6665174 Following a dynamic reconfiguration
operation using the XSCF commands
deleteboard(8) and addboard(8), you might
see I/O channel degradation, resulting in error
messages and entries in the corresponding
ereport.
If you run into this problem, the fmdump(8)
command will show a report:
ereport.chassis.SPARCEnterprise.asi
c.ioc.ch.leaf.fe
This error can be cleared. You can clear the
errors using the following commands.
To identify the resource, use:
fmadm faulty -ia
To clear the resource, run the following
command using the uuid resource
identified from the previous command:
fmadm repair resource
6675409 If COD licensed capacity is changed while a
COD board is undergoing DR, some of the
COD CPUs might be marked as Faulted.
This will require a service action to correct.
Do not attempt to modify the COD licensed
capacity while a DR operation is in progress
on a COD board.
COD licensed capacity is modified by adding
or removing licenses (with the
addcodlicense or deletecodlicense
commands) or by changing headroom (with
the setcod command). Do not use these
commands (or equivalent browser operations)
while a DR operation is in progress. You can
change the COD licensed capacity after the DR
operation is completed.
6679286 When you use the command setsnmpusm
passwd to set a password, if you set a
password of fewer than eight characters, a
segmentation fault occurs.
Always set a password of at least eight
characters.