User`s guide

Sun SPARC Enterprise M8000/M9000 Servers Product Notes 13
6545143 When kcage daemon is expanding the kcage
area, if the user stack exists in the expanded
area, its area is demapped and might cause a
ptl_1 panic during the flushw handler
execution.
There is no workaround.
6545685 If the system has detected Correctable
MemoryErrors (CE) at power-on self-test
(POST), the domains might incorrectly
degrade 4 or 8 DIMMs.
Increase the memory patrol timeout values used
via the following setting in /etc/system and
reboot the system:
set mc-opl:mc_max_rewrite_loop =
20000
6546188 The system panics when running hot-plug
(cfgadm) and DR operations (addboard and
deleteboard)on the following cards:
X4447A-Z, PCI-e Quad-port Gigabit Ethernet
Adapter UTP
X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet
Fiber XFP Low profile Adapter
There is no workaround.
6551356 The system panics when running hot-plug
(cfgadm) to configure a previously
unconfigured card. The message "WARNING:
PCI Expansion ROM is not accessible" will be
seen on the console shortly before the system
panic. The following cards are affected by
this defect:
X4447A-Z, PCI-e Quad-port Gigabit Ethernet
Adapter UTP
X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet
Fiber XFP Low profile Adapter
Note - Do not use cfgadm -c unconfigure
to disconnect the I/O card. Use cfgadm -c
disconnect to completely remove the card.
After waiting at least 10 seconds, the card
might be configured back into the domain
using the cfgadm -c configure command.
6556742 The system panics when DiskSuite cannot
read the metadb during DR. This bug affects
the following cards:
SG-XPCIE2FC-QF4, 4Gb PCI-e Dual-Port
Fibre Channel HBA
SG-XPCIE1FC-QF4, 4Gb PCI-e Single-Port
Fibre Channel HBA
SG-XPCI2FC-QF4, 4Gb PCI-X Dual-Port
Fibre Channel HBA
SG-XPCI1FC-QF4, 4Gb PCI-X Single-Port
Fibre Channel HBA
Panic can be avoided when a duplicated copy of
the metadb is accessible via another Host Bus
Adaptor.
TABLE 6 Solaris OS Issues and Workarounds Fixed in Solaris 10 5/08 (2 of 4)
CR ID Description Workaround