24 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP 1070 April 2008
d. Wait until XSCF firmware reaches the ready state.
This can be confirmed when the READY LED of the XSCF remains lit, or the
following message appears on the serial console:
12. Turn off all the server power switches for 30 seconds.
13. After 30 seconds, turn the power switches back on.
14. Wait until XSCF firmware reaches the ready state.
This can be confirmed when the READY LEDs of XSCF_B#0 and XSCF_B#1
remain lit.
15. Log on to XSCFU#0 using a serial connection or LAN connection.
16. Confirm no abnormality has occurred by using the showlogs error -v and
showstatus commands.
Because XSCF#1 is not yet running XCP 1070, XSCF#0 is unable to communicate
with XSCF#1. Therefore, it is normal that showstatus will show that XSCF#1 has
faulted.
If you encounter any hardware abnormality of the XSCF contact your authorized
service representative.
17. Confirm and update the imported XCP image again.
Specify the XCP version to be updated. In this example, it is 1070. XSCF#1 will be
updated, and then XSCF#0 updated, again.
When the firmware update for XSCF#0 is complete, XSCF#1 is active.
18. Log in to XSCFU#1 using a serial connection or LAN connection.
19. Confirm completion of the update by using the showlogs event command.
XSCF> rebootxscf
The XSCF will be reset. Continue? [y|n] :y
XSCF Initialize complete
XSCF> showlogs error -v
XSCF> showstatus
XSCF> flashupdate -c update -m xcp -s 1070