Sun SPARC Enterprise M8000/M9000 Servers Product Notes 25
Confirm no abnormality is found during the update.
20. Confirm that both the current and reserve banks of XSCFU#0 display the
updated XCP versions.
If the Current and Reserve banks on XSCF#0 do not indicate XCP revision 1070,
contact your authorized service representative.
21. Confirm that switching over between XSCF units works properly.
a. Switch between the Active and Standby states:
b. When the READY LED on XSCFU_B#1 remains lit, log in to XSCFU#0 using
a serial connection or LAN connection.
c. Confirm XSCF#1 is now the standby, and that XSCF#0 has become the active
unit:
d. Confirm no new errors have been recorded since the check in Step 16:
XSCF> showlogs event
XSCF> version -c xcp
XSCF#1 (Active )
XCP0 (Reserve): 1070
XCP1 (Current): 1070
XSCF#0 (Standby)
XCP0 (Reserve): 1070
XCP1 (Current): 1070
XSCF> switchscf -t Standby
The XSCF unit switch between the Active and Standby states.
Continue? [y|n] :y
XSCF> showhardconf
XSCF> showlogs error