7 Serial Command Communications
7.7.2 Control Commands
7-12
RDSTnnnnnnnn
Registration Distance Specification
Setting range: 0 nnnnnnnn 99999999 [Reference units]
Specifies the registration distance that is used in the RS, RSnnnnnnnn, RSAnnnnnnnn, and
RSInnnnnnnn commands.
Note: Alarm E23A will occur (the motor will become servo OFF state) if the /RGRT signal
latched but the registration distance is longer than the deceleration distance.
OK
RSPDnnnnnnnn
Registration Speed Specification
Setting range: 1 nnnnnnnn 99999999 [1000 reference units/min]
Specifies the registration speed.
After the control power supply is turned ON, the registration speed set in parameter PnB27 will
be used until the speed is specified with this command.
Note: If a new registration speed is specified during registration operation, the new speed will
become effective from the next registration operation.
OK
Control Commands (cont’d)
Serial Command Function/Description
Positive
Response
x
y
/RGRT
POSa
RDSTb
SPDx
RSPDy
b
Speed