User`s manual

7.7 Serial Commands
7-29
7
Serial Command Communications
7.7.6 Zone Table Setup Commands
The following table shows the Zone Table Setup Commands.
Zone Table Setup Commands
Serial Command Function/Description Positive Response
ZONESTORE
Zone Table Save
Saves the zone table in flash memory.
Once ZONESTORE is executed, the zone table will be retained
after the control power supply is turned OFF. Because the zone
table is stored in flash memory, this command must not be exe-
cuted frequently.
OK
ZONEINIT
Zone Table Initialization
Resets all values in the zone table to their factory settings.
OK
ZONEPTzz
Zone Table ZONEP Read
Reads the ZONEP value (positive side zone boundary position.)
zz: Zone number (ZONE ID)
ZONEPT123 = +12345678 [CR] [LF]
ZONEPTzz = nnnnnnnn
Zone Table ZONEP Write
Sets the ZONEP value (positive side zone boundary position).
zz: Zone number (ZONE ID)
Settings: 99999999 nnnnnnnn +99999999
OK
ZONENTzz
Zone Table ZONEN Read
Reads the ZONEN value (negative side zone boundary posi-
tion.)
zz: Zone number (ZONE ID)
ZONENT123 = +12345678 [CR] [LF]
ZONENTzz = nnnnnnnn
Zone Table ZONEN Write
Sets the ZONEN value (negative side zone boundary position).
zz: Zone number (ZONE ID)
Settings: 99999999 nnnnnnnn +99999999
OK