User`s manual

8.1 Overview
8-3
8
Operation of Digital Operator
8.1.3 Reading the Screen
The SERVOPACK status is always displayed at the top left of the screen ( ).
BB: Base blocked
RUN: Servomotor is ON
A. : Alarm/warning is in effect ( is the alarm/warning code).
PT NT: Forward run and reverse run prohibited (Over travel)
*
P-OT: Forward run prohibited (Over travel)
*
N-OT: Reverse run prohibited (Over travel)
*
P-LS: Forward software limit
*
N-LS: Reverse software limit
*
NO-OP: Setting disabled or setting error
HBB: During hard wire base block
Overtravel and software limit indications are supported by the following software version.
INDEXER Module: Version 3 or later
SERVOPACK: Version 001B or later.
The figure of editing screen used in the program tables, ZONE tables and JOG speed tables has the follow-
ing elements.
: The article and table number currently selected
: The article of the table
: The table number
: The table settings
Note: The line beneath POS000 shows that this indication is flashing. This line does not appear on the actual screen. Note
also that the part that flashes is referred to as the cursor in this document.
㧮㧮ޓޓޓޓޓ㧙㧼㧳㧹ޓ㧱㨐㨕㨠㧙
㧼㧻㧿㧜㧜㧜㧩㧵㧗㧝㧞㧟㧠㧡㧢㧣㧤
㧼㧻㧿㧜㧜㧝㧩㧭㧗㧝㧞㧟㧠㧡㧢㧣㧤
㧼㧻㧿㧜㧜㧞㧩㧗㧵㧺㧲㧵㧺㧵㨀㧱
㧼㧻㧿㧜㧜㧟㧩㧿㨀㧻㧼

c
d
e
f
g