User`s manual

8.2 Operation of Utility Functions
8-27
8
Operation of Digital Operator
8.2.12 INDEXER Alarm History Display (FnB0D)
This function displays the history of alarms that have occurred at the SERVOPACK and INDEXER Module.
(1) Preparation
None
(2) Operating Procedure
<Note>
The alarm history can be cleared by executing the alarm history clearance (FnB0C with mode set at ALM His-
tory) described in 8.2.11 INDEXER Alarm Reset (FnB0C). The alarm history is not cleared by either resetting
the alarms (FnB0C with mode set at ALM state) or by turning the SERVOPACK’s control power supply off.
Step Display after Operation Keys Operation
1
Press the key to open the Utility Function Mode
main menu, and move the cursor with the
keys to select FnB0D.
2
Press the key to view the alarm history.
Note: If no alarms occur, “NONE” is displayed.
3
Use the keys to scroll the alarm history.
6
Press the key to return to the Utility Function
Mode main menu.