User`s manual

9 Troubleshooting
9.1.1 List of Alarms for Command Option Attachable Type SERVOPACKs
9-8
A.Eb1
Safety Device Signal
Input Timing Error
There is an error in the timing of the safety
function input signal.
Gr.1 N/A
OFF
(open)
ON
(close)
ON
(close)
A.ED1
Command Option
Module IF Command
Timeout Error
Processing of reference from the command
option module was not completed.
Gr.2
Avail-
able
A.F10
Main Circuit Cable
Open Phase
With the main power supply ON, voltage was
low for more than 1 second in phase-R, -S or
-T.
Gr.2
Avail-
able
OFF
(open)
ON
(close)
OFF
(open)
CPF00
Digital Operator
Transmission Error 1
Digital operator (JUSP-OP05A) fails to com-
municate with the SERVOPACK (e.g., CPU
error).
N/A
Invalid
CPF01
Digital Operator
Transmission Error 2
N/A
A.− − Not an error Normal operation status −−
OFF
(open)
OFF
(open)
OFF
(open)
Alarm
Display
Alarm Name Meaning
Servomotor
Stop
Method
Alarm
Reset
Alarm Code Output
/ALO1 /ALO2 /ALO3