User`s manual

10.1 Parameter List for INDEXER Module
10-3
10
Appendix
PnB04
/START-STOP; /HOME 0 to 3 0 After restart 6.1.2, 6.4.2
PnB05
/PGMRES; /JOGP 0 to 3 0 After restart 6.1.2, 6.4.2
PnB06
/SEL0; /JOGN 0 to 3 0 After restart 6.1.2, 6.4.2
PnB07
/SEL1; /JOG0 0 to 3 0 After restart 6.1.2, 6.4.2
(cont’d)
Parameter
No.
Name Setting Range
Setting
Unit
Factory
Setting
When
Enabled
Reference
Setting
Meaning
Mode 0 Mode 1
0
Starts program table operation when /START-STOP signal
is ON (close).
Stops program table operation when /START-STOP signal
is OFF (open).
Starts homing when input signal is ON (close).
1
Starts program table operation when /START-STOP signal
is OFF (open).
Stops program table operation when /START-STOP signal
is ON (close).
Starts homing when input signal is OFF (open).
2, 3 Does not start program table operation. Does not start homing.
Setting
Meaning
Mode 0 Mode 1
0
Resets program table operation by switching /PGMRES
signal from OFF (open) to ON (close). Program table oper-
ation is canceled.
Executes JOG operation in the forward direction when
input signal is ON (close).
1
Resets program table operation by switching /PGMRES
signal from ON (close) to OFF (open). Program table oper-
ation is canceled.
Executes JOG operation in the forward direction when
input signal is OFF (open).
2, 3 Does not reset program table operation. Does not execute JOG operation.
Setting
Meaning
Mode 0 Mode 1
0
When input signal is ON (close), program table selection
signal /SEL0 becomes active.
Executes JOG operation in the reverse direction when input
signal is ON (close).
1
When input signal is OFF (open), program table selection
signal /SEL0 becomes active.
Executes JOG operation in the reverse direction when input
signal is OFF (open).
2 Program table selection signal /SEL0 is always active. Does not execute JOG operation.
3 Program table selection signal /SEL0 is always inactive. Does not execute JOG operation.
Setting
Meaning
Mode 0 Mode 1
0
When input signal is ON (close), program table selection
signal /SEL1 becomes active.
When input signal is ON (close), JOG speed table selection
signal /JOG0 becomes active.
1
When input signal is OFF (open), program table selection
signal /SEL1 becomes active.
When input signal is OFF (open), JOG speed table selec-
tion signal /JOG0 becomes active.
2 Program table selection signal /SEL1 is always active. JOG speed table selection signal /JOG0 is always active.
3 Program table selection signal /SEL1 is always inactive. JOG speed table selection signal /JOG0 is always inactive.