User`s manual

10 Appendix
10-4
PnB08
/SEL2; /JOG1 0 to 3 0 After restart 6.1.2, 6.4.2
PnB09
/SEL3; /JOG2 0 to 3 0 After restart 6.1.2, 6.4.2
PnB0A
/SEL4; /JOG3 0 to 3 0 After restart 6.1.2, 6.4.2
PnB0B
/SEL5 0 to 3 0 After restart 6.1.2
PnB0C
/SEL6 0 to 3 0 After restart 6.1.2
(cont’d)
Parameter
No.
Name Setting Range
Setting
Unit
Factory
Setting
When
Enabled
Reference
Setting
Meaning
Mode 0 Mode 1
0
When input signal is ON (close), program table selection
signal /SEL2 becomes active.
When input signal is ON (close), JOG speed table selection
signal /JOG1 becomes active.
1
When input signal is OFF (open), program table selection
signal /SEL2 becomes active.
When input signal is OFF (open), JOG speed table selec-
tion signal /JOG1 becomes active.
2 Program table selection signal /SEL2 is always active. JOG speed table selection signal /JOG1 is always active.
3 Program table selection signal /SEL2 is always inactive. JOG speed table selection signal /JOG1 is always inactive.
Setting
Meaning
Mode 0 Mode 1
0
When input signal is ON (close), program table selection
signal /SEL3 becomes active.
When input signal is ON (close), JOG speed table selection
signal /JOG2 becomes active.
1
When input signal is OFF (open), program table selection
signal /SEL3 becomes active.
When input signal is OFF (open), JOG speed table selec-
tion signal /JOG2 becomes active.
2 Program table selection signal /SEL3 is always active. JOG speed table selection signal /JOG2 is always active.
3 Program table selection signal /SEL3 is always inactive. JOG speed table selection signal /JOG2 is always inactive.
Setting
Meaning
Mode 0 Mode 1
0
When input signal is ON (close), program table selection
signal /SEL4 becomes active.
When input signal is ON (close), JOG speed table selection
signal /JOG3 becomes active.
1
When input signal is OFF (open), program table selection
signal /SEL4 becomes active.
When input signal is OFF (open), JOG speed table selec-
tion signal /JOG3 becomes active.
2 Program table selection signal /SEL4 is always active. JOG speed table selection signal /JOG3 is always active.
3 Program table selection signal /SEL4 is always inactive. JOG speed table selection signal /JOG3 is always inactive.
Setting Meaning
0 When input signal is ON (close), program table selection signal /SEL5 becomes active.
1 When input signal is OFF (open), program table selection signal /SEL5 becomes active.
2 Program table selection signal /SEL5 is always active.
3 Program table selection signal /SEL5 is always inactive.
Setting Meaning
0 When input signal is ON (close), program table selection signal /SEL6 becomes active.
1 When input signal is OFF (open), program table selection signal /SEL6 becomes active.
2 Program table selection signal /SEL6 is always active.
3 Program table selection signal /SEL6 is always inactive.