User`s manual

3 SERVOPACK Installation
3.1.1 Installation Environment
3-2
3.1 SERVOPACK Installation Environment and Applicable
Standards
SERVOPACK installation environment and applicable standards are as follows.
3.1.1 Installation Environment
Surrounding air temperature: 0°C to 55°C
Ambient humidity: 90% RH or less (with no condensation)
Altitude: 1,000 m or less
Vibration resistance: 4.9 m/s
2
Shock resistance: 19.6 m/s
2
Installation Precautions
Mounting in a Control Panel
To prevent the temperature around the SERVOPACK from exceeding 55°C, take into account the size of the
control panel, the layout of the SERVOPACK, and the cooling method. For details, refer to 3.2 SERVOPACK
Installation.
Mounting Near a Heating Unit
To prevent the temperature around the SERVOPACK from exceeding 55°C, suppress radiant heat from the
heating unit and temperature rise due to convection.
Mounting Near a Vibration Source
To prevent vibration from being transmitted to the SERVOPACK, install a vibration isolator underneath the
SERVOPACK.
Mounting to a Location Exposed to Corrosive Gas
Take measures to prevent exposure to corrosive gas. Corrosive gases will not immediately affect the SERVO-
PACK, but will eventually cause electronic components and contactor-related devices to malfunction.
Other Locations
Do not mount the SERVOPACK in locations subject to high temperatures, high humidity, dripping water, cut-
ting oil, dust, iron filings, or radiation.
<Note>
When storing the SERVOPACK with the power OFF, store it in an environment with the following tempera-
ture and humidity:
•-20°C to +85°C, 90% RH or less (with no condensation)
3.1.2 Installation Conditions for Applicable Standards
Applicable
Standards
UL508C
EN50178, EN55011/A2 group1 classA, EN61000-6-2, EN61800-3, EN61800-5-1, EN954-1,
IEC61508-1 to 4
Operating
Conditions
Overvoltage category:III
Pollution degree: 2
Protection class: IP10
Installation
Conditions
UL Standard and Low Voltage Directive:
Satisfy the conditions outlined in
Σ
-V Series AC SERVOPACK SGDV Safety Precautions (TOBP
C710800 10)
EMC Directive:
Certification is required after installation in the users machine under the conditions outlined in
3.3 EMC Installation Conditions.