User`s manual

4.1 System Configuration Diagram
4-5
4
Wiring and Connection
4.1.3 Connecting to SGDV-DE1A SERVOPACK
∗1. Use a 24-VDC power supply with double insulation or reinforced insulation. (The power supply is not included.)
∗2. Before connecting an external regenerative resistor to the SERVOPACK, refer to
Σ
-V Series User's Manual Design
and Maintenance Rotational Motor/Command Option Attachable Type (SIEP S800000 60).
∗3. Use a following power supply for 90-V brake. For details, refer to
Σ
-V Series Product Catalog (KAEP S800000 42).
For 200-V input voltage: LPSE-2H01-E
For 100-V input voltage: LPDE-1H01-E
Note: The connections and wiring of the power supply of the main circuit and that of the controls differ in accordance with
the SERVOPACK to be used. For details, refer to
Σ
-V Series User's Manual Design and Maintenance Rotational
Motor/Command Option Attachable Type (SIEP S800000 60).
Motor main circuit cable
Encoder cable
SGMGV/SGMSV
Servomotor
Brake power
supply
*3
Battery case
Magnetic contactor
Noise filter
Molded-case
circuit breaker
(MCCB)
Magnetic contactor
Power supply
Three-phase 400 VAC
R S T
Protects the power
supply line by shutting
the circuit OFF when
overcurrent is detected.
Used to eliminate
external noise from
the power line.
Used for
a servomotor
with a 90-V brake
Turns the servo ON
and OFF.
Install a surge absorber.
Turns the brake power
supply ON and OFF.
Install a surge absorber.
(when an absolute
encoder is used.)
When not using the safety function,
use the SERVOPACK with the safety
function jumper connector
(JZSP-CVH05-E, provided as an
accessory) inserted.
When using the safety function,
insert a connection cable specifically
for the safety function.
Safety unit
DC power supply
*1
(24 VDC)
Regenerative
resistor
*2
SGDV-DE1A
SERVOPACK
100/200 VAC
I/O signal cable
INDEXER Module
Personal computer
Connection cable
for personal computer
Digital operator
Connection cable
for digital operator
Sequence I/O
signal cable
Host controller
Serial command
communications cable