User`s manual

4 Wiring and Connection
4.1.4 Connecting to SGDV-FE5A SERVOPACK
4-6
4.1.4 Connecting to SGDV-FE5A SERVOPACK
Before connecting an external regenerative resistor to the SERVOPACK, refer to
Σ
-V Series User's Manual Design
and Maintenance Linear Motor/Command Option Attachable Type (SIEP S800000 66).
Note: The connections and wiring of the power supply of the main circuit and that of the controls differ in accordance with
the SERVOPACK to be used. For details, refer to
Σ
-V Series User's Manual Design and Maintenance Linear Motor/
Command Option Attachable Type (SIEP S800000 66).
Regenerative
resistor
*
Noise filter
Molded-case
circuit breaker
(MCCB)
Magnetic contactor
I/O signal cable
SGDV-FE5A
SERVOPACK
INDEXER Module
Power supply:
Single-phase 100 VAC
R T
Protects the power
supply line by shutting
the circuit OFF when
overcurrent is detected.
Used to eliminate
external noise from
the power line.
Turns the servo
ON and OFF.
Install a surge
absorber.
Personal computer
Connection cable
for personal computer
Digital operator
When not using the safety function,
use the SERVOPACK with the safety function
jumper connector (JZSP-CVH05-E,
provided as an accessory) inserted.
When using the safety function, insert a
connection cable specifically for the safety function.
Safety unit
Connection cable
for digital operator
Sequence I/O
signal cable
Host controller
Serial command
communications cable
Main circuit cable
for linear servomotor
Serial converter unit
Cable for connecting
serial converter unit
Linear servomotor
with core
Linear scale
(not included)
Cable for connecting
hall sensor
Cable for connecting
linear scale