User`s manual

4.1 System Configuration Diagram
4-9
4
Wiring and Connection
4.1.6 Connecting to SGDV-DE5A SERVOPACK
∗1. Use a 24-VDC power supply with double insulation or reinforced insulation. (The power supply is not included.)
∗2. Before connecting an external regenerative resistor to the SERVOPACK, refer to
Σ
-V Series User's Manual Design
and Maintenance Linear Motor/Command Option Attachable Type (SIEP S800000 66).
Note: The connections and wiring of the power supply of the main circuit and that of the controls differ in accordance with
the SERVOPACK to be used. For details, refer to
Σ
-V Series User's Manual Design and Maintenance Linear Motor/
Command Option Attachable Type (SIEP S800000 66).
Noise filter
Molded-case
circuit breaker
(MCCB)
Magnetic contactor
Power supply
Three-phase 400 VAC
R S T
Protects the power
supply line by shutting
the circuit OFF when
overcurrent is detected.
Used to eliminate
external noise from
the power line.
Turns the servo ON
and OFF.
Install a surge absorber.
When not using the safety function,
use the SERVOPACK with the safety
function jumper connector
(JZSP-CVH05-E, provided as an
accessory) inserted.
When using the safety function,
insert a connection cable specifically
for the safety function.
Safety unit
SGDV-DE5A
SERVOPACK
I/O signal cable
INDEXER Module
Personal computer
Connection cable
for personal computer
Digital operator
Connection cable
for digital operator
Sequence I/O
signal cable
Host controller
Serial command
communications cable
24-VDC
power supply
*1
Linear servomotor
with core
Linear scale
(not included)
Cable for connecting
hall sensor
Main circuit cable for linear servomotor
Serial converter unit
Cable for connecting
serial converter unit
Cable for connecting
linear scale
Regenerative
resistor
*2