User`s manual

4 Wiring and Connection
4.2.1 I/O Signal Names and Functions
4-12
Signal Name Pin No. Function
+24V/COM 1 Power Supply for Sequence Signals. Voltage range: 24 VDC ± 10%
/MODE 0/1 3
This pin switches between Mode 0 and Mode 1.
ON: Mode 0 (program table operation)
OFF: Mode 1 (JOG speed table operation or homing)
/START-STOP;
/HOME
5
Mode 0: When ON, starts or restarts program table operation. Refers to signals /SEL0
through /SEL7 when starting operation.
When OFF, interrupts program table operation.
Mode 1: When ON, starts or restarts homing.
When OFF, interrupts homing.
/PGMRES;
/JOGP
7
Mode 0: When ON while program table operation is interrupted, resets program table
operation.
Mode 1: When ON, causes forward JOG operation.
When OFF, stops forward JOG operation.
/SEL0; /JOGN 9
Mode 0: Program table 0
Mode 1: When ON, causes reverse JOG operation.
When OFF, stops reverse JOG operation.
/SEL1; /JOG0 11
Mode 0: Program table selection 1
Mode 1: JOG speed table selection 0
/SEL2; /JOG1 13
Mode 0: Program table selection 2
Mode 1: JOG speed table selection 1
/SEL3; /JOG2 15
Mode 0: Program table selection 3
Mode 1: JOG speed table selection 2
/SEL4; /JOG3 17
Mode 0: Program table selection 4
Mode 1: JOG speed table selection 3
/SEL5 14
Mode 0: Program table selection 5
Mode 1:
/SEL6 16
Mode 0: Program table selection 6
Mode 1:
/SEL7 18
Mode 0: Program table selection 7
Mode 1: