User`s manual

4.3 Serial Command Communications Connector (CN12)
4-19
4
Wiring and Connection
4.3.2 Communications Connector
(1) Connector Model
4.3.3 Connector Signal Names
INDEXER
Module-end
Connector
Applicable Receptacles
Solder Type Case Manufacturer
10214-52A2PL
14P
10114-3000PE 10314-52A0-008 Sumitomo 3M Limited
Pin No. Signal Name Signal Circuit Name Signal Direction
1 TXD Transmit data (not inverted) Host controller INDEXER Module
2 /TXD Transmit data (inverted) Host controller INDEXER Module
3 RXD Receive data (not inverted) Host controller INDEXER Module
4 /RXD Receive data (inverted) Host controller INDEXER Module
5 GND Signal ground (0 V)
6 /RXD Receive data (inverted)
7 RT
If RT and /RXD are connected (shorted), the built-in terminator (120
Ω) will be connected
between RXD and /RXD.
8 TXD Transmit data (not inverted) Host controller INDEXER Module
9 /TXD Transmit data (inverted) Host controller INDEXER Module
10 RXD Receive data (not inverted) Host controller INDEXER Module
11 Reserved Reserved pin
12 Reserved Reserved pin
13 Reserved Reserved pin
14 GND Signal ground (0 V)