User`s manual

xi
Wiring
CAUTION
Be sure to wire correctly and securely.
Failure to observe this caution may result in motor overrun, injury, or malfunction.
Do not connect a commercial power supply to the U, V, or W terminals for
the servomotor connection.
Failure to observe this caution may result in injury or fire.
Securely connect the main circuit power supply terminals and servomotor
connection terminals.
Failure to observe this caution may result in fire.
Do not bundle or run the main circuit cables together with the I/O signal
cables or the encoder cables in the same duct. Keep them separated by at
least 30 cm.
Failure to do so may result in malfunction.
Use shielded twisted-pair wires or multi-core shielded twisted-pair wires for
I/O signal cables and the encoder cables.
I/O signal cables must be no longer than 3 m, encoder cables must be no
longer than 50 m, and control power supply (+24 V, 0 V) cables for a 400 V
input SERVOPACK must be no longer than 10 m.
Do not touch the power terminals while the CHARGE lamp is ON after turn-
ing power OFF because high voltage may still remain in the SERVOPACK.
Make sure the charge indicator is off first before starting an inspection.
Observe the following precautions when wiring main circuit terminals.
Remove detachable main circuit terminals from the SERVOPACK prior to wir-
ing.
Insert only one main circuit cable per opening in the main circuit terminals.
Make sure that no part of the core wire comes into contact with (i.e., short-cir-
cuit) adjacent wires.
Install a battery at either the host controller or the battery unit of the
encoder, but not both.
It is dangerous to install batteries at both ends simultaneously, because that sets up
a loop circuit between the batteries.
Always use the specified power supply voltage.
An incorrect voltage may result in fire or malfunction.
Take appropriate measures to ensure that the input power supply is sup-
plied within the specified voltage fluctuation range. Be particularly careful in
places where the power supply is unstable.
An incorrect power supply may result in damage to the product.
Install external breakers or other safety devices against short-circuiting in
external wiring.
Failure to observe this caution may result in fire.
Take appropriate and sufficient countermeasures for each form of potential
interference when installing systems in the following locations.
Locations subject to static electricity or other forms of noise
Locations subject to strong electromagnetic fields and magnetic fields
Locations subject to possible exposure to radioactivity
Locations close to power supplies
Failure to observe this caution may result in damage to the product.