User`s manual

2.1 Installation Environment and Applicable Standards
2-3
2
Installation
2.1.2 SERVOPACK Installation Environment
Surrounding air temperature: 0 to 55°C
Ambient humidity: 90% RH or less (with no condensation)
Altitude: 1,000 m or less
Vibration resistance: 4.9 m/s
2
Shock resistance: 19.6 m/s
2
Installation Precautions
Mounting in a Control Panel
To prevent the temperature around the SERVOPACK from exceeding 55°C, take into
account the size of the control panel, the layout of the SERVOPACK, and the cooling
method. For details, refer to 2.3 SERVOPACK Installation.
Mounting Near a Heating Unit
To prevent the temperature around the SERVOPACK from exceeding 55°C, suppress
radiant heat from the heating unit and temperature rise due to convection.
Mounting Near a Vibration Source
To prevent vibration from being transmitted to the SERVOPACK, install a vibration
isolator underneath the SERVOPACK.
Mounting to a Location Exposed to Corrosive Gas
Take measures to prevent exposure to corrosive gas. Corrosive gases will not imme-
diately affect the SERVOPACK, but will eventually cause electronic components and
contactor-related devices to malfunction.
Other Locations
Do not mount the SERVOPACK in locations subject to high temperatures, high
humidity, dripping water, cutting oil, dust, iron filings, or radiation.
<Note>
When storing the SERVOPACK with the power OFF, store it in an environment with
the following temperature and humidity:
-20 to +85°C, 90% RH or less. (with no condensation)