User`s manual

2 Installation
2.4.1 SGDV-01A (Analog Pulse Model)
2-12
2.4 EMC Installation Conditions
This section describes the recommended installation conditions that satisfy EMC
guidelines for each model of the SGDV SERVOPACK. The conditions required for
the standard type (base-mounted) of SERVOPACK are described. Refer to this sec-
tion for other SERVOPACK models such as the rack-mounted types as well.
This section describes the EMC installation conditions satisfied in test conditions
prepared by Yaskawa. The actual EMC level may differ depending on the actual sys-
tem’s configuration, wiring, and other conditions. However, because this product is
built-in, check that the following conditions are still met after being installed in the
users product.
The applicable standards are EN55011/A2 group 1 class A, EN61800-3, and
EN61000-6-2.
2.4.1 SGDV-01A (Analog Pulse Model)
Single-phase 100 V
•SGDV-F01A ( = R70, R90, 2R1, 2R8)
Symbol Cable Name Specification
c I/O signal cable Shield cable
d Safety signal cable Shield cable
e Motor main circuit cable Shield cable
f Encoder cable Shield cable
g Main circuit cable Shield cable
Power supply:
Single-phase
100 VAC
U, V, W
L1, L2
L1C, L2C
CN2
CN1
Shield box
SERVOPACK
PE
PE
Encoder
Servomotor
Brake
1
3
4
5
Clamp
Noise
filter
Brake Power
Supply
Clamp
Clamp
Clamp
CN8
2
Surge
absorber
Two turn
One turn
CoreCore
Core
Core Core
Core
Two turn
Two turn
Clamp
Host
controller
Safety unit
One turn