User`s manual

3 Wiring and Connection
3.2.1 Connecting to SGDV-01A SERVOPACK (Analog Pulse Model)
3-4
SGDV-A01A
Using a Three-phase, 200-V Power Supply
∗1. Use a 24 VDC power supply. (not included)
∗2. Before connecting an external regenerative resistor to the SERVOPACK, refer to 3.4 Con-
necting Regenerative Resistors.
200 VAC
SGMJV/SGMAV/SGMPS/
SGMGV/SGMSV
Servomotor
R S T
SGDV-A01A
SERVOPACK
Power supply
Three-phase 200 VAC
Noise filter
Molded-case
circuit breaker
(MCCB)
Protects the power supply
line by shutting the
circuit OFF when
overcurrent is
detected.
Used to eliminate
external noise from
the power line.
Magnetic
contactor
Turns the servo
ON and OFF.
Install a surge
absorber.
Brake power supply*
1
Regenerative
resistor*
2
Used for a servomotor
with a brake.
Turns the brake power supply
ON and OFF.
Install a surge absorber.
Motor main
circuit cable
Encoder cable
When not using the safety
function, use the SERVOPACK
with the safety function jumper
connector (JZSP-CVH05-E,
provided as an accessory)
inserted.
When using the safety function,
insert a connection cable
specifically for the safety function.
Safety function
devices
I/O signal cable
Connection cable
for digital operator
Connection cable
for personal computer
Digital
operator
Personal
computer
Host controller
Battery case
(when an absolute
encoder is used.)
Magnetic contactor