User`s manual

3.4 Connecting Regenerative Resistors
3-33
3
Wiring and Connection
SERVOPACKs: Model SGDV-470A, 550A, 590A, 780A, 210D, 260D,
280D, 370D
No built-in regenerative resistor is provided, so the external regenerative resistor is
required. The regenerative resistor units are as follow:
Connect a regenerative resistor unit between B1/ and B2 terminals.
When using a regenerative resistor unit, set Pn600 to 0W (factory setting).
Main
Circuit
Power
Supply
Applicable
SERVOPACK
Model SGDV
Applicable
Regenerative
Resistor Unit
Resistance
(Ω)
Specifications
Three-
phase
200 V
470A JUSP-RA04-E
6.25
25 Ω (220 W); 4 resistors in paral-
lel
550A, 590A,
780A
JUSP-RA05-E
3.13
25 Ω (220 W); 8 resistors in paral-
lel
Three-
phase
400 V
210D, 260D JUSP-RA18-E
18
18 Ω (220 W); 2 resistors in series
with 2 in parallel.
280D, 370D JUSP-RA19-E
14.25
28.5 Ω (220 W); 2 resistors in
series with 4 in parallel.
Regenerative Resistor Unit
JUSP-RA-E
SERVOPACK