User`s manual

12
3.4 Rotary Switches
Use these switches to set the baud rate and the station number of the CC-Link.
Before turning ON the inverter's power supply, set these three switches. Do not change the
settings after turning ON the power supply. Be sure to change the settings after turning OFF
the inverter power supply.
3.4.1 Baud Rate Setting Switches
Switch 0 1 2 3 4
Communications
Speed
156 kbps 625 kbps 2.5 Mbps 5 Mbps 10 Mbps
Note: If this switch is set to 5 or higher, the LED lamp "L.ERR" lights resulting in a
communications error.
3.4.2 Station No. Setting Switches
1. The station number is set in the range of 1 to 64.
"STA×10" sets the 2nd order of the station number.
"STA×1" sets the 1st order of the station number.
Example 1) Setting the station number to 32:
Set "STA×10" to 3.
Set "STA×1" to 2.
Example 2) Setting the station number to 8:
Set "STA×10" to 0.
Set "STA×1" to 8.